# Annual gas safety check by a Gas Safe registered engineer

> Have each relevant gas appliance and flue safety-checked by a Gas Safe registered engineer within 12 months of installation and then at least every 12 months. For a new lease, the statutory timing rule allows the first check of a newly installed appliance or flue to fall after the lease starts.

- Status: In force since 3 Oct 1998 (`in_force`)
- Topic: Safety
- Confidence: High
- Rule id: `gas-safety-annual-check`
- Web page: https://lettance.com/rules/gas-safety-annual-check

## Who it applies to

Any residential letting in England under a lease within reg 36(1), or a licence (including lodgers and rooms in an HMO), where the landlord provides a gas appliance, installation pipework or flue, or one that serves the premises and is owned or controlled by the landlord. The statutory lease definition includes short, periodic and specified statutory tenancies, subject to its break-clause and renewal-option rules. Appliances the tenant owns and is entitled to remove are excluded.

## What you must do

Ensure each relevant gas appliance and flue is checked for safety (including the matters in regulation 26(9)) by, or by an employee of, a Gas Safe registered business: within 12 months of installation and at intervals of not more than 12 months since the last check. For a new lease, the check must have taken place within the preceding 12 months or take place within 12 months of installation, whichever is later (reg 36(3)(b)). This does not remove the continuous duty to keep fittings and flues safe, the requirement for registered gas work, or the duties to make and retain records of checks and give the applicable records to tenants. A check completed in the 2 months before the deadline date is treated as made on the deadline date, so the original anniversary is kept. Separately, once per appliance or flue, a check may be made up to 2 months after the deadline date, but only to align its date with another appliance or flue in the same premises.

Deadline: Every 12 months. Next check is due within 12 months of the previous check (the deadline date). A check done up to 2 months early keeps the original deadline date for the following check (reg 36A(1)). For a new lease, apply reg 36(3)(b): a check within the preceding 12 months or within 12 months of installation, whichever is later, subject to reg 36A.

## Evidence to keep

- Gas safety record for each check containing the items listed in reg 36(3)(c)
- Engineer's Gas Safe registration number on the record
- Records of any remedial work carried out after the check

## If you do not comply

- Criminal offence: yes
- Other consequences: Breach is a criminal offence under the Health and Safety at Work etc. Act 1974 s.33(1)(c), enforced by HSE: on conviction on indictment up to 2 years' imprisonment and/or an unlimited fine; on summary conviction imprisonment up to the magistrates' court general limit and/or a fine. In licensed HMOs and licensed houses, producing an annual gas safety certificate to the council is also a mandatory licence condition.

## The law

- [Gas Safety (Installation and Use) Regulations 1998 (SI 1998/2451), reg 36(1)-(4) (scope, maintenance, check timing and records)](https://www.legislation.gov.uk/uksi/1998/2451/regulation/36)
- [Gas Safety (Installation and Use) Regulations 1998, reg 36A (inserted by SI 2018/139 from 6 April 2018)](https://www.legislation.gov.uk/uksi/1998/2451/regulation/36A)
- [Health and Safety at Work etc. Act 1974, Schedule 3A (mode of trial and maximum penalty)](https://www.legislation.gov.uk/ukpga/1974/37/schedule/3A)

## Official guidance

- [HSE: Gas safety checks - who needs them?](https://www.hse.gov.uk/gas/landlords/safetycheckswho.htm)
- [HSE: Gas safety check - who can do it?](https://www.hse.gov.uk/gas/landlords/safetycheckswhocan.htm)
- [HSE: Gas safety checks - what if...?](https://www.hse.gov.uk/gas/landlords/safetycheckswhatif.htm)

## Notes

HSE: lodgers paying rent make the householder a landlord for reg 36; the duty cannot be passed to a tenant by contract. Regulation 36(1) includes periodic and specified statutory tenancies as well as leases of less than 7 years. A landlord's right to end a longer fixed term before 7 years, or a tenant's renewal option taking a shorter term to 7 years or more, can change that classification; do not rely on the stated fixed-term length alone. If the tenant refuses access, HSE expects repeated, documented attempts. Section 21 was abolished from 1 May 2026, so the former link between gas records and section 21 notices no longer matters for new possession claims.

---

From Lettance: https://lettance.com/rules/gas-safety-annual-check (catalogue edition 28 November 2026). This is information, not legal advice. Check the linked sources before you act.